2026 Rule Compliance Deadlines

Rule 463: Organic Liquid Storage
Beginning June 7, 2026, owners or operators of internal floating roof tanks must install secondary seals in accordance with Rule 463 requirements. Secondary seals must be added at the time of the next internal API 653 inspection or the next time the tank is cleaned and degassed, whichever occurs first.

Rule 1146.2: Emissions of Oxides of Nitrogen from Large Water Heaters and Small Boilers and Process Heaters
Beginning January 1, 2026, Type 1 units with a rated heat input capacity less than or equal to 400,000 Btu per hour and instantaneous water heaters with a rated heat input capacity less than or equal to 200,000 Btu per hour for installation in new buildings must comply with zero-emission limits.

Rule 1148.1: Oil and Gas Production Wells
Engines, gas turbines, and fuel cells using produced gas at onshore oil producing wells, well cellars, and produced gas handling and maintenance operations must meet a lower NOx standard and begin source testing starting August 2, 2026.

Rule 1151: Motor Vehicle and Mobile Equipment Non- Assembly Line Coating Operations
Automotive refinishing coatings, with the exception of color coatings, containing tert-Butyl Acetate (t-BAc) or para- Chlorobenzotriflouride (pCBtF) may not be manufactured for sale or use in South Coast AQMD after May 1, 2025. Coatings manufactured before that date may continue to be sold for use in South Coast AQMD until May 1, 2026, and may continue to be used in the South Coast AQMD until July 1, 2027. Automotive refinishing color coatings containing t-BAc or pCBtF may not be manufactured for sale or use in South Coast AQMD after November 1, 2025. Coatings manufactured before that date may continue to be sold for use in South Coast AQMD until November 1, 2026, and may continue to be used in the South Coast AQMD until January 1, 2028.

Rule 1159.1: Control of NOx Emissions from Nitric Acid Tanks
Facilities with one or more Nitric Acid Tanks shall, no later than January 1, 2026, demonstrate: 1) NOx emissions from nitric acid tanks are below a combined emission rate based on source tests; 2) additions of nitric acid to tanks do not exceed per tank or per facility limits; or 3) submit a permit application if installing a control device for a nitric acid tank.

Rule 1168: Adhesive and Sealant Applications
Beginning January 1, 2026:
• Clear, paintable, and immediately water-resistant sealants exceeding 250 g/L VOCs may not be manufactured for sale and use within South Coast AQMD. These products manufactured prior to January 1, 2026, may be sold until January 1, 2029, and used until January 1, 2030;
• Clear, paintable, and immediately water-resistant sealants containing pCBtF or t-BAc may not be manufactured for sale or use in South Coast AQMD. These products manufactured prior to January 1, 2026, may be sold until January 1, 2029, and used until January 1, 2030; and
• Each container of Foam Insulation, One-Component Foam Sealants, High-Pressure Two-Component Foam Sealants, and Low Pressure Two-Component Foam Sealant shall display the VOC content on the label as percent VOC by weight.

Rule 1171: Solvent Cleaning Operations
Beginning January 1, 2026, solvent cleaning materials containing pCBtF or t-BAc may not be manufactured for sale or use in South Coast AQMD. These solvent cleaning materials manufactured prior to January 1, 2026, containing t-BAc or pCBtF, may be sold until January 1, 2027, and used until July 1, 2028.

Rule 1173: Control of Volatile Organic Compound Leaks and Releases from Components at Petroleum Facilities and Chemical Plants
Operators of refineries, re-refiners, chemical plants, marine terminals, oil and gas production sites, natural gas processing plants, and pipeline transfer stations must begin monitoring all components using Optical Gas Imaging (OGI) and maintain valves, fittings, and other components below 100 ppm VOC, maintain compressors and light liquid pumps below 400 ppm VOC, and begin monitoring and tagging of fin fans by January 1, 2026.

Rule 1180: Fenceline and Community Air Monitoring for Petroleum Refineries and Related Facilities Rule 1180.1: Fenceline and Community Air Monitoring for Other Refineries

Phase two community air monitoring system fees are due by January 31, 2026.

Rule 1405: Control of Ethylene Oxide Emissions from Sterilization and Related Operations
Small and medium facilities performing EtO (ethylene oxide) sterilization must vent captured fugitive EtO emissions to a compliant control system by January 1, 2026. Small facilities sterilizing and aerating separately and all medium facilities must sterilize within a permanent total enclosure, also by January 1, 2026.

These brief rule summaries and compliance deadlines are provided for informational purposes only. Please consult the rule language available at: https://www.aqmd.gov/home/rules-compliance/rules for complete requirements. If there is a discrepancy between the information included here and the rule language adopted by the Governing Board, the official rule language shall govern.