| Aeroqual (S500-GSS)
 
   | 1650 | tVOC (MOx) |  |  | - | - | Lab 
 | 
        
            | Aeroqual (S500-PID)
 
   | 3120 | tVOC (PID) |  |  | 0.98 (low ramp)
 | 220 to 480 (low ramp)
 | Lab 
 | 
        
            | Aeroqual (S500-PID)
 
   | 3120 | tVOC (PID) |  |  | 0.99 (high ramp)
 | 50 to 1170 (high ramp)
 | Lab 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1972 | tVOC (PID) |  |  | 0.97 (low ramp)
 | 330 to 450 (low ramp)
 | Lab 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1972 | tVOC (PID) |  |  | 0.99 (high ramp)
 | 20 to 1080 (high ramp)
 | Lab 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1995 | NO (EC) | 0.29 to 0.73 | 74.3 to 212.1 |  |  | Field 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1995 | NO2 (EC) | 0.02 to 0.29 | 86.9 to 441.6 |  |  | Field 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1995 | O3 (EC) | 0.59 to 0.71 | 11.5 to 16.2 |  |  | Field 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1995 | PM1.0 | 0.86 to 0.90 | 2.0 to 2.7 |  |  | Field 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1995 | PM2.5 | 0.86 to 0.88 | 2.6 to 3.3 |  |  | Field 
 | 
        
            | SGS Galson (SmartSense)
 
   | 1995 | PM10 | 0.57 to 0.60 | 9.9 to 15.4 |  |  | Field 
 | 
        
            | Fablab (Smart Citizen
 Kit v2.1)
 
   | 119 | tVOC (MOx) |  |  | 0.69 to 0.73 (low ramp)
 | 410 to 430 (low ramp)
 | Lab 
 | 
        
            | Fablab (Smart Citizen
 Kit v2.1)
 
   | 119 | tVOC (MOx) |  |  | - (high ramp)
 | - (high ramp)
 | Lab 
 | 
        
            | PurpleAir (PA-II-FLEX VOC)
 
   | 289 | tVOC (MOx) |  |  | Negative Correlation (low ramp)
 | - (low ramp)
 
 | Lab 
 | 
        
            | PurpleAir (PA-II-FLEX VOC)
 
   | 289 | tVOC (MOx) |  |  | 0.40-0.60 (high ramp)
 | - (high ramp)
 | Lab 
 | 
        
            | Sensirion (SGP40)
 
   | 80 | tVOC (MOx) |  |  | 0.91 (low ramp)
 | 30 to 340 (low ramp)
 | Lab 
 | 
        
            | Sensirion (SGP40)
 
   | 80 | tVOC (MOx) |  |  | 0.01 (high ramp)
 | 5000 (high ramp)
 | Lab 
 | 
        
            | SENSIT (SPOD Ion XF-PID)
 
   | 3213 | tVOC (PID) |  |  | 0.99 (low ramp)
 | 150 to 260 (low ramp)
 | Lab 
 | 
        
            | SENSIT (SPOD Ion XF-PID)
 
   | 3213 | tVOC (PID) |  |  | 0.99 (high ramp)
 | 800 to 2200 (high ramp)
 | Lab 
 | 
        
            | Aeroqual (AQY-R)
 
   | 5000 | PM2.5 | 0.66 to 0.81 | 2.9 to 5.1 | 0.99 | 3.0 to 13.3 | Field Lab
 
 | 
        
            | Aeroqual (AQY v0.5)
 Discontinued
 
   | 3000 | PM2.5 | 0.84 to 0.87 | - | 0.99 | 28.8 to 36.0 | Field Lab
 
 | 
        
            | Aeroqual (AQY v1.0)
 
   | 4000 | PM2.5 | 0.76 to 0.81 | 4.2 to 5.3 | 0.99 | 5.4 to 15.1 | Field Lab
 
 | 
        
            | Aeroqual (AQY v1.0)
 
   | 4000 | PM10 | 0.56 to 0.68 | 35.4 to 38.8 | - | - | Field 
 | 
        
            | Aeroqual (S500-PM)
 
   | 1490 | PM2.5 | 0.46 to 0.67 | 4.4 to 6.2 | 0.99 | 11.9 to 32.4 | Field Lab
 
 | 
        
            | Aeroqual (S500-PM)
 
   | 1490 | PM10 | 0.15 to 0.24 | 13.5 to 18.0 | - | - | Field Lab
 
 | 
        
            | AethLabs (microAeth)
 
   | 6500 | BC | 0.79 to 0.94 | - | - | - | Field 
 | 
        
            | Airly 
   | 1000 | PM1.0 | 0.79 to 0.89 | 4.2 to 5.3 | - | - | Field 
 | 
        
            | Airly 
   | 1000 | PM2.5 | 0.83 to 0.89 | 4.5 to 5.0 | - | - | Field 
 | 
        
            | Airly 
   | 1000 | PM10 | 0.34 to 0.37 | 19.3 to 19.7 | - | - | Field 
 | 
        
            | Air Quality Egg (2018 Model)
 
   | 249 | PM1.0 | 0.86 to 0.88 | 2.1 to 2.3 | 0.99 | 7.0 to 7.3 | Field Lab
 
 | 
        
            | Air Quality Egg (2018 Model)
 
   | 249 | PM2.5 | 0.84 to 0.85 | 4.4 to 5.3 | 0.99 | 6.1 to 6.6 | Field Lab
 
 | 
        
            | Air Quality Egg (2018 Model)
 
   | 249 | PM10 | 0.12 to 0.13 | 16.4 to 19.2 | - | - | Field Lab
 
 | 
        
            | Air Quality Egg (Ver. 1)
 
   | 200 | PM | 0 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 2)
 
   | 240 | PM2.5 | 0.79 to 0.85 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 2)
 
   | 240 | PM10 | 0.31 to 0.40 | - | - | - | Field 
 | 
        
            | Air Quality Egg (2022 Model)
 
   | 671 | PM1.0 | 0.84 to 0.89 | 2.9 to 3.9 | - | - | Field Lab
 
 | 
        
            | Air Quality Egg (2022 Model)
 
   | 671 | PM2.5 | 0.88 to 0.90 | 6.0 to 7.1 | 0.99 | 5.0 to 8.0 | Field Lab
 
 | 
        
            | Air Quality Egg (2022 Model)
 
   | 671 | PM10 | 0.29 to 0.52 | 18.5 to 20.8 | - | - | Field Lab
 
 | 
        
            | AirThinx (IAQ)
 
   | 1000 | PM1.0 | 0.68 to 0.70 | 2.4 to 2.5 | - | - | Field 
 | 
        
            | AirThinx (IAQ)
 
   | 1000 | PM2.5 | 0.54 to 0.57 | 4.8 to 5.0 | - | - | Field 
 | 
        
            | AirThinx (IAQ)
 
   | 1000 | PM10 | 0.03 to 0.05 | 19.7 to 19.8 | - | - | Field 
 | 
        
            | Airviz Inc. (Speck)
 
   | 150 | PM2.5 | 0.32 | - | - | - | Field 
 | 
        
            | Alphasense (OPC-N2)
 
   | 310 | PM1.0 | 0.63 to 0.82 | - | 0.99 | - | Field Lab
 
 | 
        
            | Alphasense (OPC-N2)
 
   | 310 | PM2.5 | 0.65 to 0.80 | - | 0.99 | - | Field Lab
 
 | 
        
            | Alphasense (OPC-N2)
 
   | 310 | PM10 | 0.45 to 0.57 | - | 0.99 | - | Field Lab
 
 | 
        
            | Alphasense (OPC-N3)
 
   | 338 | PM1.0 | 0.78 to 0.82 | 4.4 to 5.0 | 0.99 | 39.0 to 43.2 | Field Lab
 
 | 
        
            | Alphasense (OPC-N3)
 
   | 338 | PM2.5 | 0.52 to 0.67 | 7.1 to 9.2 | 0.99 | 40.3 to 46.9 | Field Lab
 
 | 
        
            | Alphasense (OPC-N3)
 
   | 338 | PM10 | 0.45 to 0.52 | 18.0 to 24.1 | 0.99 | 39.2 to 48.0 | Field Lab
 
 | 
        
            | Alphasense (OPC-R2)
 
   | 435 | PM1.0 | 0.77 to 0.87 | 7.8 to 11.8 | - | - | Field Lab
 
 | 
        
            | Alphasense (OPC-R2)
 
   | 435 | PM2.5 | 0.67 to 0.78 | 7.3 to 10.0 | 0.98 | 41.2 to 45.0 | Field Lab
 
 | 
        
            | Alphasense (OPC-R2)
 
   | 435 | PM10 | 0.69 to 0.86 | 7.8 to 15.4 | 0.98 to 0.99 | 18.5 to 27.9 | Field Lab
 
 | 
        
            | Applied Particle Technology
 (MINIMA)
 
   | 995 | PM1.0 | 0.84 to 0.89 | 5.0 to 5.6 | - | - | Field Lab
 
 | 
        
            | Applied Particle Technology
 (MINIMA)
 
   | 995 | PM2.5 | 0.86 to 0.89 | 5.8 to 6.5 | 0.99 | 5.0 to 8.1 | Field Lab
 
 | 
        
            | Applied Particle Technology
 (MINIMA)
 
   | 995 | PM10 | 0.37 | 39.4 to 40.3 | - | - | Field Lab
 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | PM1.0 | 0.55 to 0.73 | 2.4 to 3.4 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | PM2.5 | 0.47 to 0.79 | 2.7 to 7.5 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | PM10 | 0.24 to 0.58 | 11.4 to 23.1 | - | - | Field 
 | 
        
            | AS-LUNG (Air Quality Station)
 
   | 2199 | PM1.0 | 0.42 to 0.88 | 3.2 to 7.3 | - | - | Field 
 | 
        
            | AS-LUNG (Air Quality Station)
 
   | 2199 | PM2.5 | 0.59 to 0.81 | 8.0 to 12.1 | - | - | Field 
 | 
        
            | AS-LUNG (Air Quality Station)
 
   | 2199 | PM10 | 0.15 to 0.23 | 18.6 to 21.2 | - | - | Field 
 | 
        
            | AS-LUNG (Portable)
 
   | 1000 | PM1.0 | 0.86 | 3.2 to 4.3 | 0.99 | 2.6 to 3.4 | Field Lab
 
 | 
        
            | AS-LUNG (Portable)
 
   | 1000 | PM2.5 | 0.78 | 6.8 to 8.2 | 0.99 | 12.8 to 13.5 | Field Lab
 
 | 
        
            | AS-LUNG (Portable)
 
   | 1000 | PM10 | 0.11 to 0.14 | 18.9 to 21.6 | - | - | Field Lab
 
 | 
        
            | Atmotube (Pro)
 
   | 189 | PM1.0 | 0.91 to 0.93 | 3.6 to 4.6 | 0.99 | 1.9 to 6.4 | Field Lab
 
 | 
        
            | Atmotube (Pro)
 
   | 189 | PM2.5 | 0.88 | 4.9 to 5.9 | 0.99 | 2.9 to 3.8 | Field Lab
 
 | 
        
            | Atmotube (Pro)
 
   | 189 | PM10 | 0.22 | 20.9 to 22.9 | - | - | Field Lab
 
 | 
        
            | Atmocube 
   | 800 | PM1.0 | 0.80 to 0.84 | 2.4 to 3.2 | - | - | Field 
 | 
        
            | Atmocube 
   | 800 | PM2.5 | 0.65 to 0.66 | 5.3 to 6.5 | - | - | Field 
 | 
        
            | Atmocube 
   | 800 | PM10 | 0.09 | 37.1 to 38.8 | - | - | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | PM1.0 | 0.89 to 0.90 | 3.7 to 4.2 | - | - | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | PM2.5 | 0.87 to 0.88 | 3.4 to 3.8 | - | - | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | PM10 | 0.28 to 0.29 | 23.9 to 24.7 | - | - | Field 
 | 
        
            | Aurassure
            (Trust Lite) 
   | 525 | PM1.0 | 0.84 to 0.85 | 2.0 to 2.3 | - | - | Field 
 | 
        
            | Aurassure
            (Trust Lite) 
   | 525 | PM2.5 | 0.65 to 0.66 | 5.0 to 5.3 | - | - | Field 
 | 
        
            | Aurassure
            (Trust Lite) 
   | 525 | PM10 | 0.07 to 0.08 | 36.9 to 37.3 | - | - | Field 
 | 
        
            | Blues Wireless (Airnote)
 
   | 149 | PM1.0 | 0.68 to 0.86 | 4.3 to 6.8 | - | - | Field 
 | 
        
            | Blues Wireless (Airnote)
 
   | 149 | PM2.5 | 0.67 to 0.75 | 4.4 to 7.1 | - | - | Field 
 | 
        
            | Blues Wireless (Airnote)
 
   | 149 | PM10 | 0.04 to 0.11 | 20.2 to 34.8 | - | - | Field 
 | 
        
            | Cair 
   | 200 | PM(1-2) | 0.43 to 0.51 | - | - | - | Field 
 | 
        
            | Cair 
   | 200 | PM(3-10) | 0.39 to 0.51 | - | - | - | Field 
 | 
        
            | Clarity (Node)
 
   | 1300 | PM2.5 | 0.73 to 0.76 | 3.0 to 3.4 | 0.99 | 9.3 to 10.6 | Field Lab
 
 | 
        
            | Davis Instruments (Airlink)
 
   | 179 | PM1.0 | 0.85 to 0.88 | 2.2 to 2.8 | - | - | Field Lab
 
 | 
        
            | Davis Instruments (Airlink)
 
   | 179 | PM2.5 | 0.74 to 0.81 | 4.9 to 5.9 | 0.99 | 4.3 to 6.6 | Field Lab
 
 | 
        
            | Davis Instruments (Airlink)
 
   | 179 | PM10 | 0.25 to 0.31 | 12.1 to 26.0 | - | - | Field Lab
 
 | 
        
            | Dylos (DC1100 Pro)
 
   | 300 | PM(0.5-2.5) | 0.65 to 0.85 | 4.2 | 0.89 | - | Field Lab
 
 | 
        
            | Dylos (DC1700-PM)
 
   | 475 | PM2.5 | 0.58 to 0.68 | 24.3 to 28.5 | 0.95 | 198.3 to 209.4 | Field Lab
 
 | 
        
            | Dylos (DC1700-PM)
 
   | 475 | PM10 | 0.15 to 0.18 | 43.9 to 53.8 | - | - | Field Lab
 
 | 
        
            | Ecowitt (WH415B)
 
   | 100 | PM2.5 | 0.35 to 0.47 | 8.2 to 15.4 | - | - | Field 
 | 
        
            | Ecomesure (EcomSmart)
 
   | 4550 | PM1.0 | 0.63 to 0.74 | 5.6 to 7.1 | 0.92 | 1.6 to 3.7 | Field Lab
 
 | 
        
            | Ecomesure (EcomSmart)
 
   | 4550 | PM2.5 | 0.54 to 0.74 | 7.0 to 9.6 | 0.92 | 5.8 to 10.9 | Field Lab
 
 | 
        
            | Ecomesure (EcomSmart)
 
   | 4550 | PM10 | 0.08 to 0.25 | 16.7 to 20.3 | - | - | Field Lab
 
 | 
        
            | Edimax (AirBox)
 
   | 249 | PM2.5 | 0.61 to 0.87 | 4.4 to 5.5 | - | - | Field 
 | 
        
            | Edimax (Edigreen Home)
 
   | 299 | PM2.5 | 0.82 to 0.83 | 3.3 to 4.4 | - | - | Field 
 | 
        
            | Elitech (Temtop LKC-1000S+)
 
   | 140 | PM2.5 | 0.91 to 0.92 | 3.1 to 3.6 | 0.99 | 11.1 to 21.9 | Field Lab
 
 | 
        
            | Elitech (Temtop LKC-1000S+)
 
   | 140 | PM10 | 0.31 to 0.35 | 11.7 to 17.9 | - | - | Field Lab
 
 | 
        
            | Elitech (Temtop M2000
 2nd Generation)
 
   | 100 | PM2.5 | 0.77 to 0.82 | 2.1 to 3.2 | 0.99 | 13.3 to 21.5 | Field Lab
 
 | 
        
            | Elitech (Temtop M2000
 2nd Generation)
 
   | 100 | PM10 | 0.17 to 0.28 | 12.1 to 14.1 | - | - | Field Lab
 
 | 
        
            | Elitech (Temtop P20)
 
   | 70 | PM2.5 | 0.42 to 0.87 | 3.8 to 6.1 | 0.99 | 5.1 to 10.7 | Field Lab
 
 | 
        
            | Elitech (Temtop PMD 351)
 
   | 960 | PM1.0 | 0.68 to 0.75 | 2.4 to 3.8 | - | - | Field Lab
 
 | 
        
            | Elitech (Temtop PMD 351)
 
   | 960 | PM2.5 | 0.71 to 0.74 | 3.8 to 5.8 | 0.99 | 26.7 to 28.8 | Field Lab
 
 | 
        
            | Elitech (Temtop PMD 351)
 
   | 960 | PM10 | 0.27 to 0.46 | 9.1 to 18.6 | - | - | Field Lab
 
 | 
        
            | Fablab (Smart Citizen
 Kit v2.1)
 
   | 119 | PM1.0 | 0.94 | 2.9 to 3.0 | 0.99 | 11.0 to 11.5 | Field Lab
 
 | 
        
            | Fablab (Smart Citizen
 Kit v2.1)
 
   | 119 | PM2.5 | 0.76 to 0.77 | 8.3 to 10.7 | 0.99 | 11.8 to 14.5 | Field Lab
 
 | 
        
            | Fablab (Smart Citizen
 Kit v2.1)
 
   | 119 | PM10 | 0.06 to 0.09 | 48.2 to 56.9 | - | - | Field Lab
 
 | 
        
            | Foobot 
   | 200 | PM2.5 | 0.55 | - | - | - | Field 
 | 
        
            | GGSensors (TAM)
 
   | 7999 | PM1.0 | 0.93 | 5.2 to 5.5 | 0.99 | 24.5 to 25.4 | Field Lab
 
 | 
        
            | GGSensors (TAM)
 
   | 7999 | PM2.5 | 0.92 | 5.4 to 5.7 | 0.99 | 21.4 to 22.3 | Field Lab
 
 | 
        
            | GGSensors (TAM)
 
   | 7999 | PM10 | 0.56 to 0.57 | 27.4 to 28.0 | - | - | Field 
 | 
        
            | HabitatMap (AirBeam)
 
   | 200 | PM2.5 | 0.65 to 0.70 | 15.6 to 29.0 | 0.87 | 203.5 to 271.9 | Field Lab
 
 | 
        
            | HabitatMap (AirBeam2)
 
   | 250 | PM1.0 |  | 2.9 to 3.0 | 0.99 | 16.5 to 18.1 | Field Lab
 
 | 
        
            | HabitatMap (AirBeam2)
 
   | 250 | PM2.5 | 0.63 to 0.75 | 3.3 to 3.7 | 0.99 | 11.3 to 13.5 | Field Lab
 
 | 
        
            | HabitatMap (AirBeam2)
 
   | 250 | PM10 | 0 | 25.8 to 28.0 | - | - | Field Lab
 
 | 
        
            | HabitatMap (AirBeam3)
 
   | 249 | PM1.0 | 0.95 to 0.97 | 1.3 to 2.6 | 0.99 | 1.5 to 5.7 | Field Lab
 
 | 
        
            | HabitatMap (AirBeam3)
 
   | 249 | PM2.5 | 0.81 to 0.90 | 3.6 to 5.3 | 0.99 | 2.6 to 11.6 | Field Lab
 
 | 
        
            | HabitatMap (AirBeam3)
 
   | 249 | PM10 | 0.19 to 0.25 | 20.4 to 26.8 | - | - | Field Lab
 
 | 
        
            | Hanvon (Hanvon N1)
 
   | 200 | PM2.5 | 0.52 to 0.79 | - | - | - | Field 
 | 
        
            | Igienair (Zaack AQI)
 
   | 3000 | PM1.0 | 0.78 to 0.83 | 6.3 to 6.5 | - | - | Field Lab
 
 | 
        
            | Igienair (Zaack AQI)
 
   | 3000 | PM2.5 | 0.80 to 0.82 | 3.8 to 4.2 | 0.97 | 5.3 to 23.0 | Field Lab
 
 | 
        
            | Igienair (Zaack AQI)
 
   | 3000 | PM10 | 0.69 to 0.71 | 14.4 to 23.9 | 0.99 | 6.0 to 13.1 | Field Lab
 
 | 
        
            | IQAir (AirVisual Outdoor)
 
   | 289 | PM1.0 | 0.52 to 0.64 | 4.5 to 5.6 | - | - | Field 
 | 
        
            | IQAir (AirVisual Outdoor)
 
   | 289 | PM2.5 | 0.54 to 0.65 | 4.4 to 6.0 | - | - | Field 
 | 
        
            | IQAir (AirVisual Outdoor)
 
   | 289 | PM10 | 0.39 to 0.60 | 10.5 to 14.4 | - | - | Field 
 | 
        
            | IQAir (AirVisual Pro)
 
   | 270 | PM2.5 | 0.69 to 0.73 | 4.4 to 4.7 | 0.99 | 26.8 to 37.0 | Field Lab
 
 | 
        
            | IQAir (AirVisual Pro)
 
   | 270 | PM10 | 0.24 to 0.41 | 16.6 to 22.7 | - | - | Field Lab
 
 | 
        
            | IQAir (AirVisual
 Pro FW1.1683)
 
   | 270 | PM2.5 | 0.63 to 0.81 | 3.5 to 5.5 | 0.99 | 1.8 to 10.8 | Field Lab
 
 | 
        
            | Kaiterra (Laser Egg 2+)
 
   | 199 | PM2.5 | 0.81 to 0.85 | 3.3 to 4.0 | 0.99 | 15.2 to 23.3 | Field Lab
 
 | 
        
            | Kaiterra (Laser Egg 2+)
 
   | 199 | PM10 | 0.17 to 0.25 | 8.0 to 17.3 | - | - | Field Lab
 
 | 
        
            | Kunak (Air A10)
 
   | 3000 | PM1.0 | - | - | 0.99 | 10.4 to 17.1 | Field Lab
 
 | 
        
            | Kunak (Air A10)
 
   | 3000 | PM2.5 | 0.69 to 0.75 | 5.4 to 6.4 | 0.99 | 4.3 to 14.4 | Field Lab
 
 | 
        
            | Kunak (Air A10)
 
   | 3000 | PM10 | 0.60 to 0.68 | 18.7 to 21.9 | 0.99 | 8.9 to 23.5 | Field Lab
 
 | 
        
            | Kunak (Air Lite)
 
   | 5033 | PM1.0 | 0.76 to 0.79 | 2.6 to 3.8 | - | - | Field 
 | 
        
            | Kunak (Air Lite)
 
   | 5033 | PM2.5 | 0.88 to 0.90 | 2.1 to 2.8 | - | - | Field 
 | 
        
            | Kunak (Air Lite)
 
   | 5033 | PM10 | 0.61 to 0.62 | 16.7 to 18.2 | - | - | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | PM1.0 | 0.85 to 0.86 | 1.9 to 2.0 | - | - | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | PM2.5 | 0.86 to 0.87 | 2.4 to 2.5 | - | - | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | PM10 | 0.66 to 0.67 | 9.2 to 11.1 | - | - | Field 
 | 
        
            | Liveable Cities (SLX-PM2.5)
 
   | 954 | PM2.5 | 0.79 to 0.83 | 6.4 to 9.1 | - | - | Field 
 | 
        
            | Liveable Cities (SLX-PM10)
 
   | 954 | PM10 | 0.71 to 0.77 | 11.9 to 18.1 | - | - | Field 
 | 
        
            | Lunar Outpost (Canary-S)
 
   | 1070 | PM2.5 | 0.83 | 3.3 to 3.8 | - | - | Field 
 | 
        
            | Lunar Outpost (Canary-S)
 
   | 1070 | PM10 | 0.14 | 27.4 to 28.6 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor A3 HW105)
 
   | 500 | PM1.0 | 0.81 to 0.85 | 4.0 to 5.2 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor A3 HW105)
 
   | 500 | PM2.5 | 0.72 to 0.81 | 5.2 to 8.9 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor A3 HW105)
 
   | 500 | PM10 | 0.15 to 0.38 | 20.3 to 29.1 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 INDUSTRIAL HW103)
 
   | 1300 | PM1.0 | 0.74 to 0.83 | 2.7 to 3.7 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 INDUSTRIAL HW103)
 
   | 1300 | PM2.5 | 0.70 to 0.78 | 4.1 to 8.1 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 INDUSTRIAL HW103)
 
   | 1300 | PM10 | 0.13 to 0.34 | 18.1 to 25.7 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 SMOGGIE-PM v1.101)
 
   | 110 | PM1.0 | 0.84 to 0.86 | 4.8 to 5.6 | 0.99 | 25.3 to 26.8 | Field Lab
 
 | 
        
            | Magnasci SRL (uRADMonitor
 SMOGGIE-PM v1.101)
 
   | 110 | PM2.5 | 0.60 to 0.81 | 2.1 to 2.8 | 0.99 | 19.5 to 22.9 | Field Lab
 
 | 
        
            | Magnasci SRL (uRADMonitor
 SMOGGIE-PM v1.101)
 
   | 110 | PM10 | 0.03 to 0.06 | 17.5 to 25.2 | - | - | Field Lab
 
 | 
        
            | Met One (C-12)
 
   | 3000 | BC | 0.66 to 0.75 | 0.10 to 0.13 | - | - | Field 
 | 
        
            | Met One (E-Sampler)
 
   | 5500 | PM1.0 | - | - | - | - | Field 
 | 
        
            | Met One (E-Sampler)
 
   | 5500 | PM2.5 | 0.55 to 0.62 | 10.9 to 15.2 | - | - | Field 
 | 
        
            | Met One (E-Sampler)
 
   | 5500 | PM10 | - | - | - | - | Field 
 | 
        
            | Met One (E-Sampler)
 
   | 5500 | TSP | - | - | - | - | Field 
 | 
        
            | Met One (ES-405)
 
   | 5200 | PM1.0 | 0.84 to 0.91 | 2.8 to 3.6 | - | - | Field Lab
 
 | 
        
            | Met One (ES-405)
 
   | 5200 | PM2.5 | 0.80 to 0.92 | 3.5 to 4.0 | 0.99 | 19.0 to 21.2 | Field Lab
 
 | 
        
            | Met One (ES-405)
 
   | 5200 | PM10 | 0.78 to 0.92 | 4.5 to 8.9 | 0.99 | 10.4 to 24.4 | Field Lab
 
 | 
        
            | Met One (Neighborhood Monitor)
 
   | 1900 | PM2.5 | 0.53 to 0.67 | 6.0 to 8.4 | - | - | Field 
 | 
        
            | Moji China (Airnut)
 
   | 150 | PM2.5 | 0.81 to 0.88 | - | - | - | Field 
 | 
        
            | Oizom (Dustroid Pro V6)
 
   | 6000 | PM1.0 | 0.83 to 0.90 | 1.7 to 3.3 | - | - | Field 
 | 
        
            | Oizom (Dustroid Pro V6)
 
   | 6000 | PM2.5 | 0.84 to 0.93 | 2.1 to 4.8 | - | - | Field 
 | 
        
            | Oizom (Dustroid Pro V6)
 
   | 6000 | PM10 | 0.59 to 0.75 | 6.7 to 14.9 | - | - | Field 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | PM1.0 | 0.82 to 0.86 | 4.5 to 5.0 | - | - | Field 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | PM2.5 | 0.76 to 0.81 | 5.4 to 6.1 | 0.97 | 20.0 to 20.7 | Field Lab
 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | PM10 | 0.33 to 0.34 | 14.3 to 15.5 | - | - | Field 
 | 
        
            | Origins (Laser Egg)
 
   | 200 | PM2.5 | 0.58 | - | - | - | Field 
 | 
        
            | Origins (Laser Egg)
 
   | 200 | PM10 | 0 | - | - | - | Field 
 | 
        
            | PAMAir (Airmazing
 PAS-OA-320-3G)
 
   | 500 | PM2.5 | 0.84 to 0.86 | 3.8 to 4.0 | - | - | Field 
 | 
        
            | Perkin Elmer (ELM)
 
   | 5200 | PM | 0 | 20.6 to 30.5 | - | - | Field 
 | 
        
            | Piera Systems (Canaree R1)
 
   | 299 | PM1.0 | 0.82 to 0.91 | 3.2 to 4.5 | 0.99 | 4.4 to 11.5 | Field Lab
 
 | 
        
            | Piera Systems (Canaree R1)
 
   | 299 | PM2.5 | 0.69 to 0.90 | 6.3 to 7.2 | 0.99 | 31.3 to 44.0 | Field Lab
 
 | 
        
            | Piera Systems (Canaree R1)
 
   | 299 | PM10 | 0.19 to 0.35 | 16.3 to 22.6 | - | - | Field Lab
 
 | 
        
            | Plume Labs (Flow 2)
 
   | 199 | PM1.0 | 0.01 to 0.14 | - | - | - | Field 
 | 
        
            | Plume Labs (Flow 2)
 
   | 199 | PM2.5 | 0.01 to 0.13 | 7.3 to 10.6 | - | - | Field 
 | 
        
            | Plume Labs (Flow 2)
 
   | 199 | PM10 | 0 to 0.04 | 19.3 to 28.3 | - | - | Field 
 | 
        
            | PM Monitor (iMonPM)
 
   | 1995 | PM1.0 | 0.77 to 0.89 | 2.2 to 3.8 | 0.98 | 1.1 to 2.4 | Field Lab
 
 | 
        
            | PM Monitor (iMonPM)
 
   | 1995 | PM2.5 | 0.76 to 0.89 | 3.4 to 4.3 | 0.98 | 2.7 to 4.1 | Field Lab
 
 | 
        
            | PM Monitor (iMonPM)
 
   | 1995 | PM10 | 0.38 to 0.62 | 12.0 to 17.8 | 0.99 | 8.2 to 9.4 | Field Lab
 
 | 
        
            | PurpleAir (PA-I)
 
   | 150 | PM1.0 | 0.93 to 0.95 | - | 0.95 | - | Field Lab
 
 | 
        
            | PurpleAir (PA-I)
 
   | 150 | PM2.5 | 0.90 to 0.92 | - | 0.99 | - | Field Lab
 
 | 
        
            | PurpleAir (PA-I)
 
   | 150 | PM10 | 0.32 to 0.44 | - | 0.97 | - | Field Lab
 
 | 
        
            | PurpleAir (PA-I-Indoor)
 
   | 180 | PM1.0 | - | - | 0.99 | 5.1 to 9.5 | Field Lab
 
 | 
        
            | PurpleAir (PA-I-Indoor)
 
   | 180 | PM2.5 | 0.75 | - | 0.99 | 18.7 to 27.7 | Field Lab
 
 | 
        
            | PurpleAir (PA-I-Indoor)
 
   | 180 | PM10 | 0.36 to 0.46 | - | 0.97 | 4.4 to 20.4 | Field Lab
 
 | 
        
            | PurpleAir (PA-II)
 
   | 200 | PM1.0 | 0.96 to 0.98 | - | 0.99 | 11.7 to 15.9 | Field Lab
 
 | 
        
            | PurpleAir (PA-II)
 
   | 200 | PM2.5 | 0.93 to 0.97 | - | 0.99 | 1.7 to 4.2 | Field Lab
 
 | 
        
            | PurpleAir (PA-II)
 
   | 200 | PM10 | 0.66 to 0.70 | - | 0.95 | 15.6 to 20.5 | Field Lab
 
 | 
        
            | PurpleAir (PA-II-FLEX)
 
   | 299 | PM1.0 | 0.91 to 0.94 | 1.4 to 2.2 | 0.99 | 13.5 to 14.6 | Field Lab
 
 | 
        
            | PurpleAir (PA-II-FLEX)
 
   | 299 | PM2.5 | 0.78 to 0.88 | 3.4 to 3.8 | 0.99 | 1.7 to 2.2 | Field Lab
 
 | 
        
            | PurpleAir (PA-II-FLEX)
 
   | 299 | PM10 | 0.21 to 0.39 | 15.3 to 24.8 | - | - | Field Lab
 
 | 
        
            | Qingping (Air Monitor)
 
   | 135 | PM2.5 | 0.86 to 0.90 | 1.8 to 2.3 | - | - | Field 
 | 
        
            | Qingping (Air Monitor Lite)
 
   | 96 | PM2.5 | 0.85 to 0.93 | 1.8 to 3.6 | - | - | Field 
 | 
        
            | Qingping (Air Monitor Lite)
 
   | 96 | PM10 | 0.37 to 0.43 | 16.2 to 20.1 | - | - | Field 
 | 
        
            | QuantAQ (MODULAIR-PM)
 
   | 1295 | PM1.0 | 0.87 to 0.94 | 4.1 to 6.8 | - | - | Field 
 | 
        
            | QuantAQ (MODULAIR-PM)
 
   | 1295 | PM2.5 | 0.84 to 0.88 | 4.0 to 5.2 | - | - | Field 
 | 
        
            | QuantAQ (MODULAIR-PM)
 
   | 1295 | PM10 | 0.46 to 0.78 | 14.7 to 21.6 | - | - | Field 
 | 
        
            | Redspira 
   | 180 | PM2.5 | 0.73 to 0.87 | 4.7 to 7.1 | 0.99 | 11.4 to 16.2 | Field Lab
 
 | 
        
            | Redspira 
   | 180 | PM10 | 0.31 to 0.37 | 30.8 to 33.1 | - | - | Field Lab
 
 | 
        
            | RTI (MicroPEM)
 
   | 2000 | PM2.5 | 0.65 to 0.90 | 6.4 to 8.3 | 0.99 | - | Field Lab
 
 | 
        
            | SailBri Cooper (SCI-901)
 
   | 5500 | PM2.5 | 0.79 to 0.89 | 2.2 to 3.1 | - | - | Field 
 | 
        
            | SailBri Cooper (SCI-901)
 
   | 5500 | PM10 | 0.64 to 0.82 | 5.6 to 14.1 | - | - | Field 
 | 
        
            | SainSmart (Pure MorningP3)
 
   | 170 | PM2.5 | 0.71 to 0.74 | 4.8 to 5.4 | 0.99 | - | Field Lab
 
 | 
        
            | SamyoungS&C (SY-DS-DK3)
 
   | 100 | PM2.5 | 0.60 to 0.62 | 4.8 to 11.4 | 0.98 | 36.1 to 51.8 | Field Lab
 
 | 
        
            | Sensirion (Nubo)
            Discontinued
 
   | 2000 | PM1.0 | 0.96 | 2.8 to 3.2 | 0.99 | 1.9 to 4.5 | Field Lab
 
 | 
        
            | Sensirion (Nubo)
            Discontinued
 
   | 2000 | PM2.5 | 0.91 | 4.7 to 5.2 | 0.99 | 4.9 to 7.6 | Field Lab
 
 | 
        
            | Sensirion (Nubo Air)
 
   | 1700 | PM1.0 | 0.77 to 0.89 | 2.9 to 3.5 | - | - | Field 
 | 
        
            | Sensirion (Nubo Air)
 
   | 1700 | PM2.5 | 0.73 to 0.83 | 5.2 to 6.5 | - | - | Field 
 | 
        
            | Sensirion (SEN44)
 
   | 53 | PM1.0 | 0.89 | 1.6 to 1.7 | - | - | Field 
 | 
        
            | Sensirion (SEN44)
 
   | 53 | PM2.5 | 0.82 | 2.9 to 3.0 | - | - | Field 
 | 
        
            | Sensirion (SEN44)
 
   | 53 | PM10 | 0.22 | 20.7 to 20.8 | - | - | Field 
 | 
        
            | Sensirion (SEN54)
 
   | 23 | PM1.0 | 0.87 to 0.88 | 2.1 to 2.4 | - | - | Field 
 | 
        
            | Sensirion (SEN54)
 
   | 23 | PM2.5 | 0.76 to 0.77 | 3.5 | - | - | Field 
 | 
        
            | Sensirion (SEN54)
 
   | 23 | PM10 | 0.18 to 0.19 | 28.6 to 28.7 | - | - | Field 
 | 
        
            | Sensirion (SPS30)
 
   | 100 | PM1.0 | 0.91 | 1.3 to 1.4 | 0.99 | 0.8 to 1.4 | Field Lab
 
 | 
        
            | Sensirion (SPS30)
 
   | 100 | PM2.5 | 0.80 to 0.83 | 2.0 to 5.1 | 0.99 | 5.4 to 6.5 | Field Lab
 
 | 
        
            | Sensirion (SPS30)
 
   | 100 | PM10 | 0.07 to 0.20 | 10.8 to 24.7 | - | - | Field Lab
 
 | 
        
            | Shinyei (PM Evaluation Kit)
 
   | 1000 | PM2.5 | 0.80 to 0.89 | - | 0.93 | - | Field Lab
 
 | 
        
            | Strop de aer 
   | 175 | PM2.5 | 0.71 to 0.77 | 6.3 to 8.8 | 0.99 | 29.0 to 32.0 | Field Lab
 
 | 
        
            | Strop de aer 
   | 175 | PM10 | 0.15 to 0.26 | 19.5 to 30.7 | - | - | Field Lab
 
 | 
        
            | Tera Sensor (NextPM)
 
   | 70 | PM1.0 | 0.89 to 0.94 | 2.1 to 4.6 | - | - | Field Lab
 
 | 
        
            | Tera Sensor (NextPM)
 
   | 70 | PM2.5 | 0.87 to 0.95 | 3.9 to 5.6 | 0.99 | 30.2 to 32.0 | Field Lab
 
 | 
        
            | Tera Sensor (NextPM)
 
   | 70 | PM10 | 0.34 to 0.66 | 26.2 to 31.6 | 0.99 | 23.9 to 24.4 | Field Lab
 
 | 
        
            | TSI (AirAssure)
 
   | 1500 | PM2.5 | 0.81 to 0.83 | - | 0.99 | 32.4 to 55.0 | Field Lab
 
 | 
        
            | TSI (BlueSky)
 
   | 400 | PM2.5 | 0.65 to 0.76 | 4.9 to 5.9 | 0.99 | 3.1 to 6.2 | Field Lab
 
 | 
        
            | TSI (BlueSky)
 
   | 400 | PM10 | 0.09 to 0.21 | 22.7 to 26.3 | - | - | Field Lab
 
 | 
        
            | uHoo 
   | 300 | PM2.5 | 0 | 9.5 to 17.8 | - | - | Field 
 | 
        
            | 2B Technologies (POM)
 
   | 4500 | O3 (UV, FEM) | 1 | 1.0 to 1.9 | 0.99 | 3.7 to 14.5 | Field Lab
 
 | 
        
            | Aeroqual (AQY-R)
 
   | 5000 | NO2 (EC) | 0.82 to 0.86 | 2.8 to 3.1 | 0.99 | 28.7 to 66.1 | Field Lab
 
 | 
        
            | Aeroqual (AQY-R)
 
   | 5000 | O3 (MOx) | 0.94 to 0.98 | 3.0 to 4.8 | 0.99 | 7.7 to 27.4 | Field Lab
 
 | 
        
            | Aeroqual (AQY v0.5)
 Discontinued
 
   | 3000 | NO2 (EC) | 0.77 | - | 0.98 | - | Field Lab
 
 | 
        
            | Aeroqual (AQY v0.5)
 Discontinued
 
   | 3000 | O3 (MOx) | 0.95 | - | 0.98 | - | Field Lab
 
 | 
        
            | Aeroqual (AQY v1.0)
 
   | 4000 | NO2 (EC) | 0.60 to 0.77 | 4.1 to 5.3 | - | - | Field 
 | 
        
            | Aeroqual (AQY v1.0)
 
   | 4000 | O3 (MOx) | 0.96 to 0.97 | 2.4 to 7.3 | - | - | Field 
 | 
        
            | Aeroqual (S-500)
 
   | 500 | O3 (MOx) | 0.85 | - | 0.99 | - | Field Lab
 
 | 
        
            | Airly 
   | 1000 | NO2 (EC) | 0.54 to 0.80 | 42.4 to 48.1 | - | - | Field 
 | 
        
            | Airly 
   | 1000 | O3 (EC) | 0.90 to 0.94 | 19.3 to 22.9 | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 1)
 
   | 200 | CO (MOx) | 0 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 1)
 
   | 200 | NO2 (MOx) | 0.4 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 1)
 
   | 200 | O3 (MOx) | 0.85 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 2)
 
   | 240 | CO (EC) | 0 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 2)
 
   | 240 | NO2 (EC) | 0 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 2)
 
   | 240 | O3 (EC) | 0.0 to 0.20 | - | - | - | Field 
 | 
        
            | Air Quality Egg (Ver. 2)
 
   | 240 | SO2 (EC) | - | - | - | - |  | 
        
            | Air Quality Egg (2022 Model)
 
   | 671 | CO (EC) | 0.60 to 0.78 | 150 to 210.0 | - | - | Field 
 | 
        
            | Air Quality Egg (2022 Model)
 
   | 671 | NO2 (EC) | 0.39 to 0.55 | 20.8 to 32.0 | 0.99 | 5.5 to 61.8 | Field Lab
 
 | 
        
            | Air Quality Egg (2022 Model)
 
   | 671 | O3 (EC) | 0.20 to 0.51 | 13.2 to 18.0 | 0.98 | 4.7 to 21.0 | Field Lab
 
 | 
        
            | Air Quality Egg (2024 Model)
 
   | 1914 | CO (EC) | 0.38 to 0.74 | 125.3 to 207.4 |  |  | Field 
 | 
        
            | Air Quality Egg (2024 Model)
 
   | 1914 | NO2 (EC) | 0.80 to 0.81 | 32.9 to 36.2 |  |  | Field 
 | 
        
            | Air Quality Egg (2024 Model)
 
   | 1914 | O3 (EC) | 0.56 to 0.74 | 18.9 to 22.8 |  |  | Field 
 | 
        
            | APIS 
   | 4995 | CO (EC) | 0.87 to 0.90 | 70.0 to 99.8 | - | - | Field 
 | 
        
            | APIS 
   | 4995 | NO (EC) | 0.87 to 0.97 | 1.3 to 2.6 | - | - | Field 
 | 
        
            | APIS 
   | 4995 | NO2 (EC) | 0.30 to 0.44 | 6.1 to 9.4 | - | - | Field 
 | 
        
            | APIS 
   | 4995 | O3 (EC) | 0.73 to 0.83 | 14.2 to 19.1 | - | - | Field 
 | 
        
            | AQMesh (V4.0)
 Discontinued
 
   | 10000 | CO (EC) | 0.42 to 0.80 | - | - | - | Field 
 | 
        
            | AQMesh (V4.0)
 Discontinued
 
   | 10000 | NO (EC) | 0.0 to 0.44 | - | - | - | Field 
 | 
        
            | AQMesh (V4.0)
 Discontinued
 
   | 10000 | NO2 (EC) | 0.0 to 0.46 | - | - | - | Field 
 | 
        
            | AQMesh (V4.0)
 Discontinued
 
   | 10000 | O3 (EC) | 0.46 to 0.83 | - | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | CO (EC) | 0.90 to 0.94 | 40.0 to 52.3 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | NO (EC) | 0.67 to 0.76 | 10.9 to 12.3 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | NO2 (EC) | 0.49 to 0.54 | 7.6 to 8.4 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | NOx (EC) | 0.73 to 0.84 | 15.0 to 18.9 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | O3 (EC) | 0.62 to 0.74 | 12.9 to 14.4 | - | - | Field 
 | 
        
            | AQMesh (v3.0 PM, v5.1 Gas)
 
   | 7800 | SO2 (EC) | - | - | - | - | Field 
 | 
        
            | Atmocube 
   | 800 | CO (EC) | 0.0 to 0.11 | 218.2 to 699.2 |  |  | Field 
 | 
        
            | Atmocube 
   | 800 | O3 (EC) | 0.65 to 0.83 | 34.0 to 36.7 |  |  | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | CO (EC) | 0.75 to 0.78 | 57.7 to 60.9 |  |  | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | NO (EC) | 0.52 to 0.87 | 8.1 to 11.5 |  |  | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | NO2 (EC) | 0.16 to 0.21 | 9.2 to 9.8 |  |  | Field 
 | 
        
            | A.U.G. Signals Ltd (AirSENCE Standard
 AS400X)
 
   | 4000 | O3 (EC) | 0.82 to 0.85 | 9.0 to 9.3 |  |  | Field 
 | 
        
            | CairPol Cairsens (CO)
 
   | 1243 | CO (EC) | 0.93 to 0.94 | 93.6 to 134.9 | - | - | Field 
 | 
        
            | CairPol Cairsens (NO2)
 
   | 1198 | NO2 (EC) | 0.0 to 0.12 | 6.0 to 14.6 | - | - | Field 
 | 
        
            | Ecomesure (EcomSmart)
 
   | 4550 | CO (EC) | 0.75 to 0.81 | 79.4 to 125.1 | 0.91 | 873.8 to 1277.5 | Field Lab
 
 | 
        
            | Ecomesure (EcomSmart)
 
   | 4550 | O3 (EC) | 0.63 to 0.64 | 11.4 to 25.7 | 0.87 | 13.4 to 30.2 | Field Lab
 
 | 
        
            | Ecomesure (EcomSmart)
 
   | 4550 | NO2 (EC) | 0.39 to 0.56 | 13.3 to 21.6 | 0.89 | 81.1 to 85.0 | Field Lab
 
 | 
        
            | Igienair (Zaack AQI)
 
   | 3000 | CO (EC) | 0.84 to 0.87 | 276.0 to 329.6 | 0.98 | 2604 to 3910 | Field Lab
 
 | 
        
            | Igienair (Zaack AQI)
 
   | 3000 | NO2 (EC) | 0.53 to 0.58 | 7.2 to 8.0 | 0.99 | 12.9 to 13.3 | Field Lab
 
 | 
        
            | Igienair (Zaack AQI)
 
   | 3000 | O3 (EC) | 0 | 20.7 to 23.9 | 0.98 | 18.0 to 24.4 | Field Lab
 
 | 
        
            | Kunak (Air A10)
 
   | 5000 | CO (EC) | 0.55 to 0.60 | 38.9 to 42.0 | - | - | Field 
 | 
        
            | Kunak (Air A10)
 
   | 5000 | NO (EC) | 0.78 to 0.93 | 1.1 to 1.7 | - | - | Field 
 | 
        
            | Kunak (Air A10)
 
   | 5000 | NO2 (EC) | 0.24 to 0.32 | 6.6 to 7.4 | - | - | Field 
 | 
        
            | Kunak (Air A10)
 
   | 5000 | O3 (EC) | 0.86 to 0.88 | 4.8 to 5.9 | - | - | Field 
 | 
        
            | Kunak (Air Lite)
 
   | 5033 | NO2 (EC) | 0.66 to 0.70 | 4.2 to 4.5 |  |  | Field 
 | 
        
            | Kunak (Air Lite)
 
   | 5033 | O3 (EC) | 0.85 to 0.89 | 4.7 to 6.8 |  |  | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | CO (EC) | 0.84 to 0.86 | 54.6 to 57.5 |  |  | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | NO (EC) | 0.99 | 2.4 to 2.9 |  |  | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | NO2 (EC) | 0.69 to 0.75 | 3.9 to 4.3 |  |  | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | NOx (EC) | 0.93 to 0.94 | 4.5 to 5.0 |  |  | Field 
 | 
        
            | Kunak (Air Pro)
 
   | 8500 | O3 (EC) | 0.85 to 0.89 | 5.6 to 6.5 |  |  | Field 
 | 
        
            | Liveable Cities (SLX-NO2)
 
   | 569 | NO2 (EC) | 0.42 to 0.55 | 18.4 to 18.8 | - | - | Field 
 | 
        
            | Liveable Cities (SLX-O3)
 
   | 569 | O3 (MOx) | 0.08 to 0.10 | 14.2 to 19.1 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 INDUSTRIAL HW103)
 
   | 1300 | CO (EC) | 0.00 to 0.07 | 224.9 to 290.7 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 INDUSTRIAL HW103)
 
   | 1300 | NO2 (EC) | 0.00 to 0.05 | 11.6 to 24.8 | - | - | Field 
 | 
        
            | Magnasci SRL (uRADMonitor
 INDUSTRIAL HW103)
 
   | 1300 | O3 (EC) | 0.00 to 0.08 | 15.0 to 19.5 | - | - | Field 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | CO (EC) | 0.64 to 0.71 | 76 to 81 | 0.35 | 2632 to 2981 | Field Lab
 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | NO (EC) | 0.10 to 0.35 | 21.1 to 24.6 | - | - | Field 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | NO2 (EC) | 0.002 to 0.03 | 20.6 to 29.1 | - | - | Field 
 | 
        
            | Oizom (Polludrone Smart)
 
   | 8000 | O3 (EC) | 0.14 to 0.23 | 18.9 to 19.7 | - | - | Field 
 | 
        
            | Perkin Elmer (ELM)
 
   | 5200 | NO (MOx) | - | - | - | - | Field 
 | 
        
            | Perkin Elmer (ELM)
 
   | 5200 | NO2 (MOx) | 0 | 11.9 to 14.1 | - | - | Field 
 | 
        
            | Perkin Elmer (ELM)
 
   | 5200 | O3 (MOx) | 0.89 to 0.96 | 4.6 to 9.8 | - | - | Field 
 | 
        
            | Plume Labs (Flow 2)
 
   | 199 | NO2 (MOx) | 0.04 to 0.14 | 11.2 to 17.6 | - | - | Field 
 | 
        
            | Smart Citizen Kit 
   | 200 | CO (MOx) | 0.50 to 0.85 | - | - | - | Field 
 | 
        
            | Smart Citizen Kit 
   | 200 | NO2 (MOx) | 0 | - | - | - | Field 
 | 
        
            | Spec Sensorss 
   | 500 | CO (EC) | 0.84 to 0.90 | - | - | - | Field 
 | 
        
            | Spec Sensorss 
   | 500 | NO2 (EC) | 0.0 to 0.16 | - | - | - | Field 
 | 
        
            | Spec Sensorss 
   | 500 | O3 (EC) | 0.0 to 0.24 | - | - | - | Field 
 | 
        
            | uHoo 
   | 300 | CO (MOx) | 0 | 360 | - | - | Field 
 | 
        
            | uHoo 
   | 300 | O3 (MOx) | 0.43 to 0.72 | 14.5 to 68.8 | - | - | Field 
 | 
        
            | UNITEC SENS-IT (CO)
 
   | 2200 | CO (MOx) | 0.33 to 0.43 | 117.1 to 736.8 | 0.99 | - | Field Lab
 
 | 
        
            | UNITEC SENS-IT (NO2)
 
   | 2200 | NO2 (MOx) | 0.57 to 0.62 | 16.2 to 20.6 | - | - | Field 
 | 
        
            | UNITEC SENS-IT (O3)
 
   | 2200 | O3 (MOx) | 0.72 to 0.83 | 11.0 to 13.4 | 0.82 to 0.90 | - | Field Lab
 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.11
 
   | 3700 | CO (EC) | 0.28 to 0.31 | - | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.11
 
   | 3700 | NO2 (EC) | 0 | - | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.11
 
   | 3700 | O3 (EC) | 0.40 to 0.58 | - | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.11
 
   | 3700 | SO2 (EC) | - | - | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.15
 
   | 3700 | CO (EC) | 0.80 to 0.83 | 222 to 234 | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.15
 
   | 3700 | NO2 (EC) | 0.43 to 0.61 | 13.0 to 16.3 | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.15
 
   | 3700 | O3 (EC) | 0.66 to 0.82 | 6.6 to 8.9 | - | - | Field 
 | 
        
            | Vaisala (AQT410)
 Ver. 1.15
 
   | 3700 | SO2 (EC) | - | - | - | - | Field 
 | 
        
            | Vaisala (AQT530)
 Ver. 3.1
 
   | 3500 | CO (EC) | 0.91 to 0.92 | 72.2 to 85.9 | 0.96 | 74.5 to 301.7 | Field Lab
 
 | 
        
            | Vaisala (AQT530)
 Ver. 3.1
 
   | 3500 | NO (EC) | 0.67 to 0.71 | 15.6 to 22.3 | - | - | Field Lab
 
 | 
        
            | Vaisala (AQT530)
 Ver. 3.1
 
   | 3500 | NO2 (EC) | 0.39 to 0.60 | 11.3 to 16.7 | 0.96 | 8.1 to 38.6 | Field Lab
 
 | 
        
            | Vaisala (AQT530)
 Ver. 3.1
 
   | 3500 | O3 (EC) | 0.22 to 0.46 | 11.2 to 13.8 | 0.97 | 3.0 to 42.5 | Field Lab
 
 | 
        
            | Air Quality Egg (2024 Model)
 
   | 1914 | PM1.0 | 0.88 to 0.89 | 4.9 to 5.7 |  |  | Field 
 | 
        
            | Air Quality Egg (2024 Model)
 
   | 1914 | PM2.5 | 0.89 | 4.2 to 4.3 |  |  | Field 
 | 
        
            | Air Quality Egg (2024 Model)
 
   | 1914 | PM10 | 0.34 to 0.35 | 40.7 to 42.1 |  |  | Field 
 | 
        
            | Particles Plus (Community CPC)
 
   | 2995 | UFP | 0.94 to 0.95 | 1045.4 to 1185.0 (#/cm3) |  |  | Field 
 | 
        
            | HabitatMap (AirBeam Mini)
 
   | 99 | PM2.5 | 0.64 | 3.1 to 3.3 |  |  | Field 
 | 
        
            | Airthings Space Pro
 
   | 385 | PM1.0 | - | - | - | - | Field 
 | 
        
            | Airthings Space Pro
 
   | 385 | PM2.5 | 0.44 to 0.49 | 5.4 to 8.3 | - | - | Field 
 | 
        
            | Airthings Space Pro
 
   | 385 | PM10 | 0.15 to 0.16 | 13.9 to 16.0 | - | - | Field 
 | 
        
            | Cubic Sensors & Instruments
 PM2012SE-B
 
   | 45 | PM1.0 | 0.71 to 0.75 | 3.3 to 3.7 | - | - | Field 
 | 
        
            | Cubic Sensors & Instruments
 PM2012SE-B
 
   | 45 | PM2.5 | 0.59 to 0.63 | 4.9 to 5.0 | - | - | Field 
 | 
        
            | Cubic Sensors & Instruments
 PM2012SE-B
 
   | 45 | PM10 | 0.1 to 0.14 | 23.7 to 24.1 | - | - | Field 
 | 
        
            | Strop de Aer PM-Ultimate
 
   | 250 | PM1.0 | 0.69 to 0.72 | 3.4 to 3.6 | - | - | Field 
 | 
        
            | Strop de Aer PM-Ultimate
 
   | 250 | PM2.5 | 0.59 to 0.60 | 4.6 to 4.7 | - | - | Field 
 | 
        
            | Strop de Aer PM-Ultimate
 
   | 250 | PM10 | 0.12 to 0.13 | 25.4 to 25.8 | - | - | Field 
 | 
        
            | QuantAQ (MODULAIR-PM; 2025 Evaluation)
 
   | 2495 | PM1.0 | - | - | - | - | Field 
 | 
        
            | QuantAQ (MODULAIR-PM; 2025 Evaluation)
 
   | 2495 | PM2.5 | 0.86 to 0.93 | 4.4 to 5.3 | - | - | Field 
 | 
        
            | QuantAQ (MODULAIR-PM; 2025 Evaluation)
 
   | 2495 | PM10 | 0.78 to 0.90 | 12.3 to 15.8 | - | - | Field 
 |